Simplicity Synergy X9 Specifications Page 308

  • Download
  • Add to my manuals
  • Print
  • Page
    / 352
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 307
Synergy Nano Technical Manual, Revision -
Page 308
Description Command Root Command
Usages
Command Syntax Range,
Units
Command
Example
Response Example
RTD Curve RTD RTD Set = RTD ARG1 ARG1:
0 - JIS
1 - DIN
= RTD 0 OK
RTD Query ? RTD 0 - JIS
1 - DIN
? RTD 0
Vaisala
Compensatio
n
VCMP VCMP Set = VCMP ARG1 ARG1:
0 - On
1 - Off
= VCMP 0 OK
VCMP Query ? VCMP 0 - On
1 - Off
? VCMP 0
1L1 1L1 1L1 Set = 1L1 ARG1 0 - 100 % = 1L1 50 OK
1L1 Query ? 1L1 0 - 100 % ? 1L1 50.00
1L2 1L2 1L2 Set = 1L2 ARG1 0 - 100 % = 1L2 20 OK
1L2 Query ? 1L2 0 - 100 % ? 1L2 20.00
1L3 1L3 1L3 Set = 1L3 ARG1 -100 to 100 C -148 to 212 F = 1L3 10 OK
1L3 Query ? 1L3 -100 to 100 C -148 to 212 F ? 1L3 10.00
1CTY 1CTY 1CTY Set = 1CTY ARG1 ARG1:
0 - CAP - Tube System
1 - Agree Logic
2 - Burn In Logic
3 - Standard XV Sys Logic
= 1CTY 1 OK
1CTY Query ? 1CTY 0 - CAP - Tube System
1 - Agree Logic
2 - Burn In Logic
3 - Standard XV Sys Logic
? 1CTY 0
2L1 2L1 2L1 Set = 2L1 ARG1 -100 - 100 % = 2L1 50 OK
2L1 Query ? 2L1 -100 - 100 % ? 2L1 50.00
2L2 2L2 2L2 Set = 2L2 ARG1 -100 - 100 % = 2L2 20 OK
2L2 Query ? 2L2 -100 - 100 % ? 2L2 50.00
2L3 2L3 2L3 Set = 2L3 ARG1 -100 to 100 C -148 to 212 F = 2L3 10 OK
2L3 Query ? 2L3 -100 to 100 C -148 to 212 F ? 2L3 50.00
2CTY 2CTY 2CTY Set = 2CTY ARG1 ARG1:
0 - CAP - Tube System
1 - Agree Logic
2 - Burn In Logic
3 - Standard XV Sys Logic
= 2CTY 1 OK