Simplicity Synergy X9 Specifications Page 240

  • Download
  • Add to my manuals
  • Print
  • Page
    / 352
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 239
Synergy Nano Technical Manual, Revision -
Page 240
14.3 Using Cascade Mode
14.3.1 Enable Cascade Mode
To enable Cascade mode, press the SETUP Screen Navigation Key and proceed to the Enabled folder
shown below (PID Settings\PID Ch 1\Cascade\Enabled)
Change the Enabled item’s value to Enabled
(Disabled is the default value).
14.3.2 Maintenance \ Channel PIDs Screen
The Channel PIDs screen shows a third column when cascade mode is enabled for the channel. All columns
show values for the following parameters: Pn, In, Dn, PID, Err, Setpoint, Actual, P.B., Reset and Rate.
The Setpoint and Actual numbers in the cascade
column are the desired setpoint, and actual
temperature of the product inside the chamber.
Setpoint & Actual values under Heating and Cooling is the air temperature.
Setpoint value under Heating and Cooling is the calculated air temperature setpoint from the Cascade
PID loop.
Cascade PID parameters: Pn, In, Dn, PID values range from -100 to +100%.
Note: -100% corresponds to the Cascade Low Limit temperature
Note: +100% corresponds to the Cascade High Limit temperature
The values in the Heating & Cooling columns range from 0 to 100%
Page view 239
1 2 ... 235 236 237 238 239 240 241 242 243 244 245 ... 351 352

Comments to this Manuals

No comments